General maintenance – SkyTrak 6036 Operation Manual User Manual

Page 130

Advertising
background image

124

Model 6036

General Maintenance

B. Hydraulic Oil Level Check

(10 Hour Intervals)

1. Be sure all cylinders are fully retracted and oil is at room temperature.

2. Level the vehicle, ground the carriage, place travel select lever in

(N) NEUTRAL, move the neutral lock lever to NEUTRAL LOCK
position, engage the parking brake switch and shut OFF the
engine.

3. Check level of hydraulic oil in tank at the sight gauge (Figure 78, 1)

on the back side of the hydraulic tank (2).

4. The oil level should be visible in the gauge window.

5. If it is not, add ISO-46 or MIL-L-2104C oil (see table on page 123).

a. Remove the four capscrews (Figure 78, 3) holding the hydraulic

oil tank cover (4) to the tank, remove the cover.

b. Turn the hydraulic oil cap (Figure 78, 5) and remove from the

filler neck. Add hydraulic oil as needed. The hydraulic oil level
should be within 1/2 inch of the upper mark on the sight gauge.

6. Install hydraulic oil cap (Figure 78, 5). Reposition the cover (4) on

the tank (2) and secure in place with the four capscrews (3).

Figure 78

10

OS0660

OH2660

OH2340

2

4

5

1

3

3

Advertising