SkyTrak 8042 Service Manual User Manual

Page 130

Advertising
background image

Transmission

6-8

6036, 6042, 8042, 10042, 10054

2. Low or no pump flow or

pressure.

1. Low oil level.

1. Fill transmission to correct level

with Mobilfluid 424

®

ISO

Grade 46. Refer to Section 2.4,
“Fluid and Lubricant
Capacities.”

2. Transmission filled with incorrect

oil, or oil contaminated.

2. Drain transmission and fill to

correct level with Mobilfluid 424

®

ISO Grade 46. Refer Section
2.4, “Fluid and Lubricant
Capacities.”

3. Pump suction pipe screen

clogged.

3. Clean, repair and/or replace

suction pipe.

4. Central shaft damaged.

4. Replace central shaft.

5. Pump worn or damaged.

5. Repair or replace pump

assembly.

3. Low clutch pressure.

1. Incorrect oil level.

1. Fill transmission to correct level

with Mobilfluid 424

®

ISO

Grade 46. Refer to Section 2.4,
“Fluid and Lubricant
Capacities.”

2. Main pressure valve stuck open.

2. Clean the valve spool and

housing.

3. Broken or worn coupling shaft or

piston o-rings.

3. Replace coupling and/or o-rings.

4. Pressure reducing valve stuck

open.

4. Clean the valve spool and

housing.

4. Lack of power.

1. Park or service brake dragging.

1. Refer to Section 8.4, “Hydraulic

Circuits.”

2. Low engine rpm causes

converter stall.

2. Adjust the engine rpm to

specifications. Refer to
Transmission Service Manual.

3. Pump output pressure is low.

3. Refer to Section 6.5,

“Transmission Troubleshooting,”
Problem 2. “Low or no pump
flow or pressure.”

4. Clutch discs worn or damaged.

4. Replace clutch discs.

5. Transmission overheating.

5. Refer to Section 6.5,

“Transmission Troubleshooting,”
Problem 5. “Transmission
overheating (oil above 120° C
(248° F)).”

Problem

Cause

Remedy

Advertising