SkyTrak 8042 Service Manual User Manual

Page 156

Advertising
background image

Hydraulic System

8-12

6036, 6042, 8042, 10042, 10054

7

PBG

D

Secondary

Function
Manifold

500-600 psi

(34-41 bar)

With engine at idle, park brake released and
steering held over relief while checking
pressure. If pressure is incorrect, adjust or
replace the pressure reducing valve in the
secondary function manifold.

8

N/A

Brake Valve

(Manual Brake

Pressure)

400 psi (28 bar)

minimum

With engine OFF, pump brake pedal twice. DO
NOT overstroke the brake pedal. If pressure is
incorrect, check for external leaks. If no leaks
are found, refer to Section 8.7.3, “Service Brake
Valve.”

8

N/A

Brake Valve

(Service

Brake

Pressure)

550 psi (38 bar)

minimum

With engine at idle, depress and hold brake
pedal. DO NOT turn steering wheel. DO NOT
overstroke the brake pedal. Check pressure. If
pressure is incorrect, refer to Section 8.7.3,
“Service Brake Valve.”

9

G1

E

Stabilizer

Cylinder

75-150 psi

(5,2-10,3 bar)

With engine at idle, check the pressure on the
cylinder.

Test

Location

Valve

Port

Adjust.

Location

Component
Description

Pressure

Reading

Pressure Test Procedures

Advertising
This manual is related to the following products: