SkyTrak 8042 Service Manual User Manual

Page 93

Advertising
background image

3-55

6036, 6042, 8042, 10042, 10054

Boom

6. Drooping chain, or jerky

boom extend or retract
functions.

1. Chain(s) tension not properly

adjusted.

1. Adjust chain(s).

2. Chain(s) stretched or binding.

2. Replace chains as needed.

Refer to Section 3.7, “Boom
Extend and Retract Chains.”

3. Wear pads loose, contaminated,

excessively worn or damaged.

3. Replace wear pad. Refer to

Section 3.9, “Boom Wear Pads.”

4. Contaminated, corroded or

rusted wear pad sliding
surfaces.

4. Remove contamination and/or

corrosion from wear pad sliding
surfaces and lubricate. If the
surfaces cannot be reconditioned,
replace the boom section(s).

5. Extend/Retract hydraulic system

not operating properly.

5. Refer to Section 8.4, “Hydraulic

Circuits.”

6. Damaged boom section.

6. Replace the damaged boom

section. Refer to Section 3.4,
“Boom Assembly Maintenance.”

7. Boom will not raise or lower.

1. Broken hydraulic hoses or tubes

and/or connection leaks.

1. Locate break, replace hose(s)

or tube(s), tighten connections.

2. Lift/Lower hydraulic system not

operating properly.

2. Refer to Section 8.4, “Hydraulic

Circuits.”

3. Faulty Lift cylinder.

3. Repair cylinder. Refer toSection

8.8.1, “General Cylinder
Instructions.”

4. Seized boom pivot pin bushing.

4. Replace bushing.

8. Excessive Lift/Lower cylinder

pivot pin noise and/or wear.

1. Insufficient lubrication.

1. Lubricate at regular intervals.

Refer to Section 2.5, “Service
and Maintenance Schedules.”

Replace worn pins as needed.
Refer to Section 8.8.1, “General
Cylinder Instructions.”

2. Worn self-aligning bushing(s).

2. Replace bushing(s) and

lubricate at regular intervals.
Refer to Section 2.6,
“Lubrication Schedules.”

Problem

Cause