5 stabil-trak system test, 1 stabil-trak system test instructions, 2 stabil-trak system test procedures – SkyTrak 8042 Service Manual User Manual

Page 221: Stabil-trak system test, Stabil-trak system test instructions, Stabil-trak system test procedures

Advertising
background image

10-7

6036, 6042, 8042, 10042, 10054

Stabil-TRAK™

System and Boom Interlock System

10.5

STABIL-TRAK SYSTEM TEST

Note: The operator must know that the Stabil-TRAK
system is active and functioning properly.

To test the function of the Stabil-TRAK system, read the
Stabil-TRAK System Test instructions and follow Steps 1
through 9 of Section 10.5.2, “Stabil-TRAK System Test
Procedures.”

10.5.1

Stabil-TRAK System Test Instructions

• Test the Stabil-TRAK system with the machine

on a level surface.

• Remove any attachment from the quick attach

before performing the test.

• DO NOT extend the boom at any time during the

test. Perform the test with the boom fully retracted.

• DO NOT raise the boom above 60° for Steps 3-6.

• DO NOT raise the boom above 45° for Steps 7-9.

• Follow Steps 1 through 9 of the Stabil-TRAK

system test procedure exactly as written.

Note: If the Stabil-TRAK light goes OFF and the front
left tire lowers to the ground at any time during Steps 4

through 7, the test was not performed properly or the
Stabil-TRAK system is not functioning properly. Carefully
repeat the steps starting with Step 1.

If the Stabil-TRAK light goes OFF and the front left tire
lowers to the ground consistently during Steps 4 through 7,
the Stabil-TRAK system is not functioning properly and
the test should be stopped immediately. If the Stabil-
TRAK system is not functioning properly, follow the
procedures in Section 10.8, “Stabil-TRAK Hydraulic
Circuit Operation and Troubleshooting,” to r
epair the
system.

10.5.2

Stabil-TRAK System Test Procedures

If Steps 1 through 9 prove positive, the Stabil-TRAK
system is functioning properly, and the machine can be
returned to service. If any of these steps indicate that the
Stabil-TRAK system is not functioning properly, follow the
procedures in Section 10.8, “Stabil-TRAK Hydraulic Circuit
Operation and Troubleshooting,” to
repair the system.