Stabil-trak™ system and boom interlock system – SkyTrak 8042 Service Manual User Manual

Page 219

Advertising
background image

10-5

6036, 6042, 8042, 10042, 10054

Stabil-TRAK™

System and Boom Interlock System

10.4

STABIL-TRAK ELECTRICAL CIRCUIT OPERATION AND TROUBLESHOOTING (6042,
8042 & 10042)

Note: Before using the 6042, 8042 and 10042
Stabil-TRAK System Troubleshooting chart and
diagrams, complete the Section 10.5, “Stabil-TRAK
System Test”
to determine what part of the system is not
functioning properly.

Definitions:
PB = Park Brake

SB = Service Brake

DE = De-energized

E = Energized

C = Closed

O = Open

6042, 8042 and 10042 Stabil-TRAK System Troubleshooting

FREE PIVOT

MODE

SLOW PIVOT

MODE

LOCKED

MODE

Machine

Conditions

Switch/
Relay
Solenoid

Ignition On

Boom Below 40°

Boom Retracted

PB & SB Released

Trans. in Forward or Reverse

Ignition On

Boom Above 40°

Boom Extended

PB & SB Released

Trans. in Forward or Reverse

Ignition On

Boom Above 40°

Boom Extended

PB & SB Applied

& Trans. in Neutral

Solenoid 12A

E

DE

DE

Solenoid 12B

E

DE

DE

Solenoid 3

DE

DE

E

Solenoid 4A

DE

E

DE

Solenoid 4B

DE

E

DE

Boom Angle Sensor

C

O

O

Boom Switch Relay

E

DE

DE

Stabilizer Lock Relay

DE

DE

E

Stabilizer Light

OFF (DE)

OFF (DE)

ON (E)

Ignition Switch

C

C

C

Park Brake Switch

O

O

C

Service Brake Switch

O

O

C

Secondary Function Manifold
Park Brake Solenoids

E

E

DE

Park Brake Disengage Relay

E

E

DE

Neutral Start Relay

DE

DE

E

Advertising