SkyTrak 8042 Service Manual User Manual

Page 153

Advertising
background image

8-9

6036, 6042, 8042, 10042, 10054

Hydraulic System

8

C

Auxiliary

Hydraulics

3000 psi

(207 bar)

With engine at low idle, move auxiliary control lever left or
right. Hold auxiliary control lever over relief and check
pressure. If pressure is incorrect, check unloader pressure
per location 2. If location 2 is ok, check port reliefs on the
aux section of main control valve.

Test

Location

Adjust.

Location

Component
Description

Pressure

Reading

Pressure Test Procedures