Stabil-TRAK™

System and Boom Interlock System

10-10

6036, 6042, 8042, 10042, 10054

10.6

STABIL-TRAK BOOM INTERLOCK ELECTRICAL CIRCUIT OPERATION AND
TROUBLESHOOTING (10054)

Note: Before using the 10054 Stabil-TRAK System
Troubleshooting chart and diagrams, complete Section
10.5, “Stabil-TRAK System Test”
and Section 10.7,
“Boom/Outrigger Interlock System Test (10054)”,
to
determine what part of the system is not functioning

properly. If an outrigger is raised or a pressure switch is
defective, boom on the 10054 will not extend beyond the
42 Series extension limit.

Definitions:

Boom Retracted = Less than 42 Series extension limit

Boom Extended = Boom at 42 Series extension limit or

greater.

PB = Park Brake

DE = De-energized

E = Energized

10054 Stabil-TRAK System Troubleshooting

BOOM EXTEND MODE 1

BOOM EXTEND MODE 2

BOOM EXTEND MODE 3

Machine

Conditions

Switch/
Relay
Solenoid

Ignition On

Boom Below 40°

Boom Retracted

PB Released

Trans. Fwd. or Rev.

Outriggers Raised

Ignition On

Boom Below 40°

Boom Extended To

42 Series Extension Limit

PB Released

Trans. Fwd. or Rev.

Outriggers Raised

Ignition On

Boom Below 40°

Boom Extended Beyond

42 Series Extension Limit

PB Applied By Interlock Sys.

Trans. In Neutral By Interlock Sys.

Outriggers Lowered

Solenoid 12A

S

ta

b

il

-TRAK

Compo

n

e

n

ts

Af

fe

c

te

d

By

Bo

om

I

n

te

rl

oc

k Sys

te

m

E

E

DE

Solenoid 12B

E

E

DE

Solenoid 3

DE

DE

E

Solenoid 4A

DE

DE

DE

Solenoid 4B

DE

DE

DE

Boom Angle Sensor

C

C

O

Boom Switch Relay

E

E

DE

Stabilizer Lock Relay

DE

DE

E

Stabilizer Light

OFF (DE)

OFF (DE)

ON (E)

Ignition Switch

C

C

C

Park Brake Switch

O

O

O

Park Brake Light

OFF (DE)

OFF (DE)

ON (E)

BOOM EXTEND INTERLOCK SYSTEM TROUBLESHOOTING

Boom Extend Interlock Sensor

C

O

O

Boom Extend Interlock Relay

E

DE

DE

Boom Extend Lockout Relay

E

DE

DE

Outrigger Pressure Switches

O

O

C

Left Outrigger Lockout Relay

DE

E

E

Right Outrigger Lockout Relay

DE

E

E

Stabilizer Interlock Relay

DE

DE

E

Stabilizer Lock-Up Relay

DE

DE

E

Extend Circuit Solenoid Valve

E

E

E

Secondary Function Manifold
Park Brake Solenoids

E

E

DE

Park Brake Interlock Relay

DE

DE

E

Park Brake Disengage Relay

E

E

DE