2 operator cab, 1 cab safety, 2 serial number decal – SkyTrak 8042 Service Manual User Manual

Page 97: 3 cab components, 1 steering column and steering valve, Operator cab, Cab components, Cab safety, Serial number decal, Steering column and steering valve

Advertising
background image

4-3

6036, 6042, 8042, 10042, 10054

Cab and Covers

4.2

OPERATOR CAB

4.2.1

Cab Safety

4.2.2

Serial Number Decal

The cab serial number decal is located on the left side of
the cab, behind the seat. Information specified on the
serial number plate includes the cab model number, the
cab serial number and other data. Write this information
down in a convenient location to use in cab
correspondence.

4.3

CAB COMPONENTS

4.3.1

Steering Column and Steering Valve

a. Steering Valve Removal

1. Park the machine on a firm, level surface, level the

machine, fully retract the boom, lower the boom,
place the travel select lever in the (N) NEUTRAL
position, engage the parking brake and turn the
engine OFF.

2. Place a Do Not Operate Tag on both the ignition key

switch and the steering wheel, stating that the
machine should not be operated.

3. Open the rear door. Allow the system fluids to cool.

4. Properly disconnect the battery.

5. Remove the left, right and lower dash panels.

6. Remove the steering wheel (1), disconnect and

remove the travel select lever (2), disconnect the
instrument panel harness connector (3).

7. Label, disconnect and cap the four hoses from the

side of the steering valve (4). Cap the fittings on the
steering valve. Label, disconnect and plug the load
sense hose at the front of the steering valve. Cap the
fitting on the steering valve.

8. Disconnect the horn button wire from the cab wiring

harness.

9. Support the bottom of the steering valve, and

remove the four capscrews and lockwashers.
Remove the steering valve through the lower dash
panel opening.

WARNING

DO NOT service the machine without following all
safety precautions as outlined in the “Safety
Practices” section of this manual.

WARNING

The protection offered by this ROPS/FOPS will be
impaired if subjected to any modification or structural
damage, at which time replacement is necessary.
ROPS/FOPS must be properly installed using
fasteners of correct size and grade, and torqued to
their specified value.

WARNING

DO NOT weld, grind, drill, repair or modify the cab in
any way. Any modification or damage to cab structural
components requires cab replacement. Refer to
Section 2.5 in the Operation & Safety Manual.

To help ensure optimum safety, protection and
performance, replace the cab if it is damaged. Refer to
the appropriate parts manual for ordering information.