11.3.8 Rotor FA-45-30-11 and rotor F-45-30-11

11.3.9 Rotor F-45-48-PCR

11.3.10 Rotor T-60-11

5804 770.005
5804 777.000
5804 738.004
5804 739.000
5804 771.001
5804 776.003
5804 772.008
5804 773.004
5804 774.000
5804 775.007

022637215
5804777000
022637279
022637282
022637223
022637274
022637231
022637240
022637258
022637266

Adapter
used in F-34-6-38
for 4 sample tubes 1.5/2.0 mL (max. Ø 11 mm), set of 2
for 1  tube 5 mL (max. Ø 17 mm), set of 2 pieces
for 3 round-bottom and blood collection tubes (13 x 75 mm), set of 2 pieces
for 3 round-bottom and blood collection tubes (13 x 100 mm), set of 2 pieces
for 2 tubes (7 bis 15 mL, max. Ø 16 mm), set of 2
for 1 conical tube (15 mL, max. Ø 17 mm), set of 2
for 1 tube (15 bis 18 mL, max. Ø 18 mm), set of 2
for 1 tube (20 bis 30 mL, max. Ø 26 mm), set of 2
for 1 tube (50 mL, max. Ø 29 mm), set of 2
for 1 conical tube (50 mL, max. Ø 29.5 mm), set of 2

Order no.
(international)

Order No.
(North America)

Description

5804 726.006

022637100

Rotor FA-45-30-11
aerosol-tight*, 45° angle, 30 places for 1.5/2.0 mL tubes, incl. rotor lid (aluminum)

5804 736.001

022637126

Rotor lid for FA-45-30-11
aerosol-tight, aluminum

5804 715.004

022637002

Rotor F 45-30-11
45° angle, 30 places for 1.5/2.0 mL tubes, incl. rotor lid (aluminum)

5804 715.403

022662970

Rotor lid for F-45-30-11
not aerosol-tight, aluminum

5425 715.005
5425 717.008
5425 716.001

022636260
022636243
022636227

Adapter
used in FA-45-30-11 and F-45-30-11
for 1 PCR tube (0.2 mL, max. Ø 6 mm), set of 6
for 1 sample tube (0.4 mL, max. Ø 6 mm), set of 6
for 1 sample tube (0.5 mL, max. Ø 6 mm) or 1 Microtainer (0.6 mL,
max. Ø 8 mm), set of 6

Order no.
(international)

Order No.
(North America)

Description

5804 735.005

022638581

Rotor F-45-48-PCR
45° angle, for 6 x 8-tube strips, 6 x 5-tube strips or 48 x 0.2 mL PCR tubes

Order no.
(international)

Order No.
(North America)

Description

5804 730.003

022638505

Rotor T 60-11
for 60 × 1.5/2.0 mL tubes
incl. rotor lid, and 6 adapters for 1.5/2 mL sample tubes

5804 731.000
5804 732.006

022638521
022638548

Adapter
used in T-60-11
for 10 sample tubes (1,5/2,0 mL, max. Ø 11 mm), set of 6
for 20 sample tubes (0.4 mL, max. Ø 6 mm), set of 6

Order no.
(international)

Order No.
(North America)

Description