SECTION 6 - DIAGNOSTIC TROUBLE CODES

6-14

– JLG Lift –

3121273

779

TRACTION T LOW - CHECK
POWER CIRCUITS

While driving, the voltage measured at
the System Module’s T terminal did not
agree with the predicted value.

• This issue may be caused by an opencircuit of the armature wir-

ing (+B and –T terminals) or an internal fault.

• VMN does not increase more than 1.3V
• VMN is less than 20% Battery Voltage
• Battery Voltage . VMN is greater than 4V
• HEALTH (Status LED) - ON

7710

PUMP P HIGH - CHECK
POWER CIRCUITS

While steering or lifting up, the voltage
measured at the System Module’s P
terminal did not agree with the predicted
value.

• This issue may be caused by a power wiring error or an internal

fault.

• Pump Feedback . Predicted >7V
• HEALTH (Status LED) - ON

7711

PUMP P LOW - CHECK
POWER CIRCUITS

While steering or lifting up, the voltage
measured at the System Module’s P
terminal did not agree with the predicted
value.

• This issue may be caused by an open-circuit of the pump wiring

(+BF2 and –P terminals) or an internal fault.

• Pump feedback does not increase more than 1.3V
• Pump feedback is less than 20% Battery Voltage
• Battery Voltage - pump feedback is greater than 4V
• HEALTH (Status LED) - ON

7741

ARMATURE BRAKING CUR-
RENT TOO HIGH

The System Module detected excessive
braking current.

• This can be caused by transporting an excessive load on a steep

grade. Alternately, this may indicate an internal fault.

• HEALTH (Status LED) - ON

7742

FIELD VOLTAGE IMPROPER The System Module voltage at the F1

and F2 terminals was improper at
power-up (expected to be ½ Battery
Voltage).

• This is caused by an open- or short-circuit in the field wiring or

motor. Disconnect the field and motor wiring from the System
Module and connect F1 / F2 with a short wire. If the situation per-
sists after a power cycle, it may be an internal issue.

• HEALTH (Status LED) - ON

8-2 LSS - Load Sensing System

(See 3124288 - LSS Manual)

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

8212

LSS PRESSURE SENSOR -
DISAGREEMENT

Pressure Sensor 1 and Pressure Sensor
2 do not agree. The system shall
assume the machine is overloaded until
the sensors agree.

• Using the Analyzer LOAD submenu under DIAGNOSTICS check

PRES1 and PRES2 readings. They must agree within 75 PSI.
With the safety prop engaged check to ensure that the appropri-
ate voltage is being supplied to both sensors and that the wiring
and connections are intact. The voltage between pins A and B
should read +5V +/- 0.5V with the machine turned on. If the
voltage supplied is correct, replace both transducers.

• HEALTH (Status LED) - ON

8213

LSS ANGLE SENSOR - DIREC-
TION DISAGREEMENT

The angle sensor’s change in reading
does not agree with the direction of the-
machine motion (lift up).

• This indicates a wiring error or Angle Sensor malfunction.
• HEALTH (Status LED) - ON

8214

LSS ANGLE SENSOR - OUT OF
RANGE HIGH

The Angle Sensor's reading when the
machine is at maximum elevation does
not fall within the high end acceptable
range

• The Angle Sensors reading must be less than or equal to 245

counts at maximum elevation.
Ensure that the Angle Sensor is mounted properly.

• HEALTH (Status LED) - ON

8215

LSS ANGLE SENSOR - OUT OF
RANGE LOW

The angle sensor’s reading when the
machine is stowed does not fall within
the low end acceptable range.

• The Angle Sensors reading must be greater than or equal to 5

counts with the platform stowed.
Ensure that the Angle Sensor is mounted properly.

• HEALTH (Status LED) - ON

8216

LSS ANGLE SENSOR HAS
NOT BEEN CALIBRATED

The Angle Sensor has never been cali-
brated and the control system assumes
that the platform is overloaded.

• Calibrate the Angle Sensor using the CALIBRATION: ANGLE sub-

menu to clear the message.

• HEALTH (Status LED) - ON

7-7 Electric Motor

DTC

FAULT MESSAGE

DESCRIPTION

CHECK