SECTION 6 - DIAGNOSTIC TROUBLE CODES

3121273

– JLG Lift –

6-15

825

LSS HAS NOT BEEN CALI-
BRATED

The Load Sensing System has never
been calibrated and the control system
assumes that the platform is over-
loaded.

• Empty Platform and Calibrate the Load Sensing System using

the calibration procedure in the LSS Manual.

• HEALTH (Status LED) - ON

8-4 Elevation Switch

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

84109

ELEVATION SWITCH CON-
TACTS DISAGREEMENT

The Elevation Switch contacts are the
same (high or low). Since the contacts
should always be complimentary, the
system assumes the platform is Ele-
vated.

• Check the wiring and the switch or replace the switch to clear the

fault.

• Health (Status LED) - ON

9-9 Hardware

DTC

FAULT MESSAGE

DESCRIPTION

CHECK

995

POWER MODULE FAILURE -
PERSONALITY RANGE
ERROR

The power module detected an out-of-
range or corrupt personality setting

• Record all personality settings in ANALYZER -> PERSONALITIES

and ANALYZER -> MACHINE SETUP. Reset control system per-
sonalities to default settings by selecting a different model than
indicated, cycle power then select proper model. Then, enter per-
sonality settings recorded above.

• Health (Status LED) - ON

996

POWER MODULE FAILURE -
INTERNAL ERROR

• This is an internal failure.
• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

998

EEPROM FAILURE - CHECK
ALL SETTINGS

The control system detected an
EEPROM failure.

• Personalities and Machine Setup settings may be reset to default

values. Check/Correct all settings and re-cycle power to clear dif-
ficulty.

• Health (Status LED) - ON

999

FUNCTION LOCKED OUT -
POWER MODULE SOFT-
WARE VERSION IMPROPER

The power module software version is
not compatible with the rest of the sys-
tem.

• Re-program or replace with a Version 1.xx module
• Health (Status LED) - ON

9950

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

9951

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

9952

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

9953

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

9954

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

9955

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

9956

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

9957

POWER MODULE FAILURE -
INTERNAL ERROR

• Cycle machine, if error still exists, replace System Module.
• HEALTH (Status LED) - FLASHING

8-2 LSS - Load Sensing System

(See 3124288 - LSS Manual)

DTC

FAULT MESSAGE

DESCRIPTION

CHECK