SECTION 5 - JLG CONTROL SYSTEM

3121273

– JLG Lift –

5-1

SECTION 5. JLG CONTROL SYSTEM

5.1 HAND HELD ANALYZER

Diagnostic Port

The diagnostic port to connect the Hand Held Analyzer is
located behind the hydraulic cover (machine left side) at
or near the ground control station as shown in Figure 5-2.

To Connect the Hand Held Analyzer:

1. Connect the four pin end of the cable supplied with

the analyzer, to the diagnostic port and connect the
remaining end of the cable to the analyzer.

NOTE: The cable has a four pin connector at each end of

the cable; the cable cannot be connected back-
wards.

2. Power up the Control System by turning the lower

key to the platform position and pulling both emer-
gency stop buttons on.

men u:

PRESS ENTER

HELP:

Analyzer Display

Escape Key

To return home or access

previous menu

Enter Key

Stores and selects Top Level, Sub

Level, and item menus

Left & Right Arrow Keys

Used to move between Top Level,

Sub Level, and item menus

Up & Down Arrow Keys

Value Selector

Figure 5-1. Hand Held Analyzer

Figure 5-2. Diagnostic Port Location