Engine start, Alternator excitation, Fuel pump – JLG 340AJ Service Manual User Manual

Page 116: Shutdown, Proportional fuel rack actuator schematic -76, Engine starter schematic -76, Alternator schematic -76

Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3-76

– JLG Lift –

3121259

PROPORTIONAL FUEL RACK ACTUATOR

The Proportional Fuel Rack Actuator controls engine speed
whenever the Control System calls for an engine RPM between
Idle and High Engine. It is energized by the J1-1 terminal on
the Ground Control Module. When the terminal is de-ener-
gized, the actuator fully extends and shuts down the engine.

Engine Start

To engage the engine starter, the Ground Module energizes
the J1-11 terminal to activate the start relay, which in turn,
energizes the starter solenoid.

Alternator Excitation

For the alternator to charge, it must be rotating and the alter-
nator excitation terminal must be energized by an external
power source. This power is supplied by the Ground Module
through terminal J1-32 to the D+ terminal on the alternator.
This terminal includes a one-way blocking diode that prevents
reverse energy flow into the Ground Module during engine
power-down. This terminal is continuously energized after
startup.

Fuel Pump

The Kubota fuel pump is mechanical and has no interaction
with the JLG Control System.

Shutdown

If the JLG Control System determines that the engine should
be shut down and not allowed to run, the Ground Module
takes the following steps to shut down the engine.

1.

Remove power and prevent power from flowing to the
Proportional Fuel Rack Actuator by turning off output
terminal J1-1.

2.

Remove power and prevent power from flowing to the
Engine Throttle Actuator by turning off output terminal
J1-2.

VBatt

J1-1 put

Out

J3-1
Current
Sense

Proportional Fuel Rack Actuator

Ground Module

Fuel Rack

Actuator

Figure 3-59. Proportional Fuel Rack Actuator Sche-

matic

VBatt

J1-11

put

Out

Starter

VBatt

Start Relay

Ground Module

-

+

Figure 3-60. Engine Starter Schematic

VBatt

J1-32 put

Out

Alternator

Ground Module

D+

Figure 3-61. Alternator Schematic

Advertising