JLG 340AJ Service Manual User Manual

Page 270

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-26

– JLG Lift –

3121259

LIFT

Accel

0.0 - 5.0sec

2.0sec

Decel

0.0 - 5.0sec

1.0sec

Min up

250 - 1400mA

400mA

Max Up

250 - 1400mA

1250mA

Creep Up

250 - 1400mA

525mA

Min Down

250 - 1400mA

400mA

Max Down

250 - 1400mA

850mA

Creep Down

250 - 1400mA

500mA

Soft Down

250 - 1400mA

500mA

TELESCOPE

Accel

0.0 - 5.0sec

1.2sec

Decel

0.0 - 5.0sec

0.5sec

Min In

250 - 1400mA

400mA

Max In

250 - 1400mA

1250mA

Creep In

250 - 1400mA

675mA

Min Out

250 - 1400mA

400mA

Max Out

250 - 1400mA

1250mA

Creep Out

250 - 1400mA

675mA

JIB LIFT

Accel

0.0 - 5.0sec

1.2sec

Decel

0.0 - 5.0sec

0.5sec

Min Up

250 - 1400mA

400mA

Max Up

250 - 1400mA

1075mA

Creep Up

250 - 1400mA

575mA

Min Down

10 - 70%

32%

Max Down

10 - 70%

53%

Creep Down

10 - 70%

48%

PLATFORM LEVEL

Accel

0.0 - 5.0sec

0.0sec

Decel

0.0 - 5.0sec

0.0sec

Min Up

250 - 1400mA

400mA

Max Up

250 - 1400mA

1250mA

Creep Up

250 - 1400mA

550mA

Min Down

250 - 1400mA

400mA

Max Down

250 - 1400mA

1250mA

Creep Down

250 - 1400mA

550mA

PLATFORM ROTATE

Accel

0.0 - 5.0sec

0.0sec

Decel

0.0 - 5.0sec

0.0sec

Min Left

250 - 1400mA

400mA

Max Left

250 - 1400mA

1250mA

Creep Left

250 - 1400mA

1250mA

Min Right

250 - 1400mA

400mA

Max Right

250 - 1400mA

1250mA

Creep Right

250 - 1400mA

1250mA

Table 6-6. Machine Model Adjustment

Adjustment

Adjustment Ranges

Default Setting

Advertising