JLG 340AJ Service Manual User Manual

Page 262

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

6-18

– JLG Lift –

3121259

Valve and Actuator Outputs

Engine Proportional Throttle Actuator

No STB/OC
No STG; energize and verify current path

Engine High Speed Throttle Actuator

No STB/OC for relay
No STG; energize to verify

Drive Forward Valve

No STB/OC
No STG; energize and verify current path

Drive Reverse Valve

No STB/OC
No STG; energize and verify current path

Swing Left Valve

No STB/OC
No STG; energize and verify current path

Swing Right Valve

No STB/OC
No STG; energize and verify current path

Tower Lift Up Valve

No STB/OC
No STG; energize and verify current path

Tower Lift Down Valve

No STB/OC
Do not check STG

Lift Up Valve

No STB/OC
No STG; energize and verify current path

Lift Down Valve

No STB/OC
Do not check STG

Flow Control Valve

No STB/OC
No STG; energize and verify current path

Telescope In Valve

No STB/OC
No STG; energize Tele In and Out simultaneously

Telescope Out Valve

No STB/OC
No STG; energize Tele In and Out simultaneously

Level Up Valve

No STB/OC
No STG; energize Level Up and Down simultaneously

Level Down Valve

No STB/OC
No STG; energize Level Up and Down simultaneously

Platform Station

Digital and Functional Switch Inputs (Platform
Module communicates and Ground Module veri-
fies)

Engine Start

Open; de-energized

Emergency Descent

Open; de-energized

Drive Speed Select

Open or Closed, but not both Max Speed and Max Torque

Horn

Open; de-energized

Tower Lift Up

Open; de-energized

Tower Lift Down

Open; de-energized

Telescope In

Open; de-energized

Telescope Out

Open; de-energized

Jib Up

Open; de-energized

Jib Down

Open; de-energized

Level Up

Open; de-energized

Level Down

Open; de-energized

Rotate Left

Open; de-energized

Rotate Right

Open; de-energized

Table 6-5. System Startup Checks

Item Checked

Function

Condition/Action

Advertising