Table 6-7. Machine Configuration Programing Information

Configuration Label/Digit

Number

Description

Default

Number

The machine configuration must be completed before any personality settings can be changed. Changing the personality settings first and then changing the model number of the
machine configuration will cause the personality settings to return to default.

MODEL NUMBER:

1

0
1
2

????: Visible only on a Non-Configured UGM
340AJ
NO MODEL

1

MARKET:

2

1
2
3
4
5
6

ANSI USA
ANSI EXPORT
CSA
CE
AUSTRALIA
JAPAN

1

ENGINE:

3

1
2

KUBOTA D1105132
DUAL FUEL ECM: GM/PSI 0.97L Duel Fuel (Tier 3)

1

FLYWHEEL TEETH:

4*

1

98 TEETH: 98 flywheel teeth.

1

* This menu item is not visible

GLOW PLUG:

5*

1

2

3

NO GLOW PLUGS: No glow plugs installed.

AIR INTAKE: Glow plugs installed in the air intake on the manifold.

IN-CYLINDER: Glow plugs installed in each cylinder.

3

* This menu item is not visible

STARTER LOCKOUT:

6*

1

2

DISABLED: Automatic pre-glow time determined by ambient air temperature; engine start can be
attempted at any time during pre-glow.

ENABLED: Automatic pre-glow time determined by ambient air temperature; engine start is NOT permitted
until pre-glow is finished.

1

* This menu item is visible only if Engine = Kubota D1105

ENGINE SHUTDOWN:

7

1

2

DISABLED: No engine shutdown.

ENABLED: Shutdown engine when coolant temperature is greater than 110 deg. C or the oil pressure is less
than 8 PSI.

2

FUEL CUTOUT:

8*

1

2

ONE START: One start with limited run time when near Empty.

ENGINE STOP: No starting permitted when near Empty.

1

* This menu item is visible only if Engine = Kubota D1105