SECTION 6 - JLG CONTROL SYSTEM

3121259

– JLG Lift –

6-69

CURRENT FEEDBACK CALI-
BRATION CHECKSUM INCOR-
RECT

9945

The current feedback gains checksum that is calculated and written
to flash memory during manufacturing is detected as being incorrect

All machine and engine func-
tions are disabled (i.e., com-
mand engine shutdown and do
not permit start).

Cycle power to clear the fault.

MACHINE CONFIGURATION
OUT OF RANGE – CHECK ALL
SETTINGS

9949

The Ground Module has detected an anomaly in stored readings for
the Machine Setup configuration.

The Ground Module prompts
the operator to correct the issue
via Analyzer and disable all
functions until stored data in
corrupted area is changed.

Cycle Power and change the
Machine Setup data.

LSS CORRUPT EEPROM

9977

The Ground Module is advising that the LSS module has detected
faulty stored parameters.

The Ground Module sets the
Platform Load State to Over-
loaded

Cycle power to clear the fault.

FUNCTIONS LOCKED OUT -
GROUND MODULE SOFTWARE
VERSION IMPROPER

9979

Ground Module detects a disagreement with internal checks on the
version of software.

All machine and engine func-
tions are disabled (i.e., com-
mand engine shutdown and do
not permit start)

Cycle power to clear the fault.

GROUND MODULE VLOW FET
FAILURE

9986

Ground Module has determined a hardware fault exists and is unable
to read high-sensing inputs.

All machine and engine func-
tions are disabled (i.e., com-
mand engine shutdown and do
not permit start)

Cycle power to clear the fault.

1

Annotated DTCs do not flash a numeric code, sound an alarm, and are not stored in annotated DTCs in Logged Help queue (this applies to most DTCs < 0100).

Table 6-10. Fault Code Troubleshooting Information

Help Message

DTC

Condition Producing DTC

Control System Response or

Machine Condition

Corrective Action/

Operational Requirement

for Function Movement

and/or to Clear Fault

Advertising