Table 6-6. Machine Model Adjustment

Adjustment

Adjustment Ranges

Default Setting

DRIVE

Max Speed Accel

25 - 2000mA/sec

275mA/sec

Max Speed Decel

25 - 2000mA/sec

175mA/sec

Max Speed Min

250 - 1800mA

640mA

Max Speed Max

250 - 1800mA

1500mA

Mid-Engine/Max Torque Accel

25 - 2000mA/sec

300mA/sec

Mid-Engine/Max Torque Decel

25 - 2000mA/sec

100mA/sec

Drive to Stop Decel

25-2000mA/sec

1075mA/sec

Drive Mid-Engine/Max Torque Min

250 - 1800mA

640mA

Max Torque Max

250 - 1800mA

1100mA

Mid-Engine Max

250 - 1800mA

1135mA

Max Torque Elevated Max

250 - 850mA

790mA

Mid-Engine Elevated Max

250 - 975mA

900mA

Max Torque Creep

250 - 750mA

725mA

Mid-Engine Creep

250 - 890mA

850mA

STEER

Accel

0.0 - 5.0sec

0.8sec

Decel

0.0 - 5.0sec

0.1sec

Min Right

10-100%

35%

Max Right

10-100%

80%

Creep Right

10-100%

50%

Min Left

10-100%

35%

Max Left

10-100%

80%

Creep Left

10-100%

50%

SWING

Accel

0.0 - 5.0sec

2.2sec

Decel

0.0 - 5.0sec

1.2sec

Min Left

250 - 1400mA

400mA

Max Left

250 - 1400mA

880mA

Creep Left

250 - 1400mA

600mA

Min Right

250 - 1400mA

400mA

Max Right

250 - 1400mA

880mA

Creep Right

250 - 1400mA

600mA

TOWER LIFT

Accel

0.0 - 5.0sec

3.0sec

Decel

0.0 - 5.0sec

1.0sec

Min up

250 - 1400mA

400mA

Max Up

250 - 1400mA

1250mA

Creep Up

250 - 1400mA

600mA

Min Down

250 - 1400mA

400mA

Max Down

250 - 1400mA

750mA

Creep Down

250 - 1400mA

450mA

Soft Down

250 - 1400mA

450mA