4 transmitter modbus supported function codes, Transmitter modbus supported function codes -3, Table 1 – CiDRA Passive Sonar Transmitters User Manual

Page 13: Supported modbus function codes -3, Table 2, Non-supported modbus function codes -3

Advertising
background image

2.4

Transmitter MODBUS Supported Function Codes

The transmitter supports these MODBUS Function Codes:

Code Sub

Code Function

01

Read

Coils

02

Read Discrete Inputs

03

Read holding Registers

04

Read Input Registers

05

Write Single Coil

06

Write Single Registers

07

Read Exception Status (Serial only)

08

Diagnostics (Serial only)

08

00

Return Query Data

08

01

Restart Communications Option

08 02

Return

Diagnostic

Register

08

03

Change ASCII Input Delimiter

08

04

Force Listen Only Mode

08

10

Clear Counters and Diagnostic Register

08

11

Return Bus Message Count

08

12

Return Bus Communications Error Count

08

13

Return Bus Exception Error Count

08

14

Return Slave Message Count

08

15

Return Slave No Response Count

08

16

Return Slave NAK Count

08

17

Return Slave Busy Count

08

18

Return Bus Character Overrun Count

08

20

Clear Overrun Counter and Flag

11

Get Communications Event Counter (Serial only)

12

Get Communications Event Log (Serial only)

15

Write Multiple Coils

16

Write Multiple Registers

17

Report Slave ID (Serial only)

22

Mask Write register

23

Read/Write Multiple registers

43 14

Read

Device

Identification

































Table 1

Supported Modbus Function Codes

The transmitter does NOT support these MODBUS Function Codes:

Code Sub

Code Function

20

Read File Record

21

Write

File

Record

24

Read FIFO Queue

Table 2

Non-Supported Modbus Function Codes

20959-01 Rev 02

Page 2-3