Table 5 Modbus Holding Registers (continued)

Address Size

Type Value

Description

Values

4055 2

Float

SOS_SAMPLE_FRE
Q

Set sample frequency for SOS mode. This parameter
must be set for SOS and overrides the SAMPLE_FREQ
setting if running in SOS mode. Enter one of the
following: 3906.25 or 2055.921.

3906.25or 2055.921

4057 2

Float

SOS_FREQ_MIN

Minimum frequency to use for SOS calculation. Typically
in the 100 to 500hz range. Depends upon the data
quality as seen on the k-w plot. SOS_FREQ_MIN and
SOS_FREQ_MAX set the frequency range over which
the SOS calculation will be performed.

4059 2

Float

SOS_FREQ_MAX

Maximum frequency to use for SOS calculation.
Typically in the 800 to 1500hz range. Depends upon the
data quality as seen on the k-w plot. SOS_FREQ_MIN
and SOS_FREQ_MAX set the frequency range over
which the SOS calculation will be performed.

4061 2

Float

SOS_MIN

Minimum SOS value to search for. If too much energy
(such as from a high velocity vortical ridge) causes the
algorithms to calculate a sound speed below that of the
main SOS ridge; this parameter may need to be
increased.

4063 2

Float

SOS_MAX

Maximum SOS value to search for. If too much energy
along the 0 k value on the k-w plot and algorithms are
calculating SOS_MAX even when SOS ridge indicates
an SOS below this value; may need to decrease this
parameter.

4065 2

Float

SOS_MIN_QUALITY

Minimum quality threshold for SOS/GVF display and
output.

4067 2

Float

SOS_CENTROID_W
IDTH

Define width of peak to use in calculation of SOS.

4069 2

Float

SOS_FREQ_THRES
H

This value selects the threshold that the second
derivative of a power array (generated at a specific
frequency over all k-space values) must break in order
for the specific frequency point to be considered a valid
frequency point.