Table 5 Modbus Holding Registers (continued)

Address Size

Type Value

Description

Values

4009 2

Float

SOS_SPECIFIC_GR
AVITY

This parameter (internally multiplied by 1000 kg/m^3) is
used to set the 'SOS Liquid Density'. For example,
Specific Gravity = 1.1 equates to density of 1.1 * 1000
kg/m^3.

4011 2

Float

SOS_LIQUID_SOS

Pure phase liquid SOS for process fluid in ft/sec. Used
for GVF calculation. Default setting is for water and is
close enough for most fluid/gas applications.

4013 2

Float

SOS_SPECFIC_HE
AT_RATIO

4015 2

Float

SOS_LIQUID_DENS
ITY

Calculated from 'SOS Specific Gravity'.

4017 2

Float

SOS_TEMPERATU
RE

Constant temperature for GVF calculations when 'Fixed'
is selected for 'SOS Temperature Input Selection'. In
configured units.

4019 2

Float

SOS_PRESSURE

Constant pressure for GVF calculations when 'Fixed' is
selected for 'SOS Pressure Input Selection'. In
configured units.

4021 2

Float

GAIN

4023 2

Float

SPL_THRESHOLD

This value is the threshold that the Average SPL must
break in order for any SOS or VF calculations to be
performed. A quality of -2 is reported if this threshold is
not met. Set this value to 0 to disable SPL.

4025

2

Float

SPL_AVG

The average SPL measurement from all active sensors.

4027 2

Float

SPL_STD_DEV

The standard deviation of the SPL measurements from
all active sensors.

4029 2

Float

SAMPLE_FREQ

Set A/D sample frequency in samples per second. Enter
one of the following: 3906.25 or 2055.921.

4031

2

Float

CHANNEL_SKEW

Flow Channel Skew.

4033 2

Float

FREQ_MIN

Set minimum frequency for k-w processing. Normally set
by DSP. User modified if using single or fixed modes or
auto mode with VF_OP_MODE_SETTINGS set to 1
(FIXED_FREQUENCY). Go to Idle mode, then set this
parameter, then select single/fixed.