20959-01 Rev 02

Page 2-4

2.5 Other

Registers

Coils and Discreet inputs are not used in the transmitter. All
configurations are performed with Holding Registers, and
measurements read from Input Registers.

2.6 Diagnostics

08/02 Read Diagnostic Register

Diagnostic Register Bits

Bit
Number

Description

0 STATUS_BIT_DEFAULTS

1 STATUS_BIT_DSP_DEAD

2 STATUS_BIT_DSP_NO_RESP

3 STATUS_PREAMP_FAILURE

4 SOS_SINGULAR_MATRIX_ERR

5 VF_SINGULAR_MATRIX_ERR

6 VFCENTROID_DIV0_ERROR

7 SOSCENTROID_DIV0_ERROR

8 NO_VALID_FREQ_POINTS

9 SENSOR_OVERLOAD_ERROR

10 VF_DATA_OVERANGE

11 SOS_DATA_OVERANGE

12 unused

13 unused

14 unused

15 unused

Table 3

Diagnostic Register Bits

2.7 Other

Functions

2.7.1

17 Read Slave ID

Slave ID returned by this command is based on the software revision
of the transmitter as follows:

Software version V4.01.02 returns a Slave ID of 40102.

2.7.2

43/14 Read Device Identification

This function code returns three string objects as follows:

CiDRA Corp.
TB8-XX-XX-XX-XX
V4.01.02