CiDRA Passive Sonar Transmitters User Manual

Page 16

Advertising
background image

Table 4 Modbus Input Registers (continued)

Address Size

Type Value

Description

Notes

33

2

Float

4-20mA Input 1

Measured analog input 1 in mA.

35

2

Float

4-20mA Input 2

Measured analog input 2 in mA.

37

2

Float

4-20mA Channel 1

Value output on 4-20mA Channel 1.

39

2

Float

4-20mA Channel 2

Value output on 4-20mA Channel 2.

41

2

Float

Sensor Alpha 1

Relative scale factor between signal magnitudes
acquired from each sensor.

43

2

Float

Sensor Alpha 2

Relative scale factor between signal magnitudes
acquired from each sensor.

45

2

Float

Sensor Alpha 3

Relative scale factor between signal magnitudes
acquired from each sensor.

47

2

Float

Sensor Alpha 4

Relative scale factor between signal magnitudes
acquired from each sensor.

49

2

Float

Sensor Alpha 5

Relative scale factor between signal magnitudes
acquired from each sensor.

51

2

Float

Sensor Alpha 6

Relative scale factor between signal magnitudes
acquired from each sensor.

53

2

Float

Sensor Alpha 7

Relative scale factor between signal magnitudes
acquired from each sensor.

55

2

Float

Sensor Alpha 8

Relative scale factor between signal magnitudes
acquired from each sensor.

57 2

Float

PreAmp Charge
Gain

Charge gain as read from the preamp.

59

2

Float

PreAmp Gain 0

Preamp Gain 0 as read from the preamp.

61

2

Float

PreAmp Gain 1

Preamp Gain 1 as read from the preamp.

63

2

Float

PreAmp Gain 2

Preamp Gain 2 as read from the preamp.

65

2

Float

PreAmp Gain 3

Preamp Gain 3 as read from the preamp.

67

2

Float

Total Flow Fraction

Floating point fraction to be added to 'Total Flow Carry'
* 100 to calculate full resolution total flow.

Fractional part of totalizer. Add
this number to Total Flow Carry *
100 to calculate full total.

20959-01 Rev 02

Page 3-1