Table 5 Modbus Holding Registers (continued)

Address Size

Type Value

Description

Values

4035 2

Float

FREQ_MAX

Set maximum frequency for k-w processing. Normally
set by DSP. User modified if using single or fixed modes
or auto mode with VF_OP_MODE_SETTINGS set to 1
(FIXED_FREQUENCY). Go to Idle mode, then set this
parameter, then select single/fixed.

4037 2

Float

FLOW_MIN

Minimum valid flow rate reading in configured display
units.

4039 2

Float

FLOW_MAX

Maximum valid flow rate reading in configured display
units.

4041

2

Float

MIN_QUALITY

Minimum quality threshold for VF display and output.

4043 2

Float

VF_NYQUIST_HIGH

Define high end of frequency range to use for
determining flow velocity. Defined by:
FREQUENCY_MAX = (Measured Velocity *
VF_NYQUIST_HIGH) / (Sensor Spacing). Example: (10
ft/sec * 0.7) / 0.2 = 35Hz

4045 2

Float

VF_NYQUIST_LOW

Define low end of frequency range to use for determining
flow velocity. Defined by: FREQUENCY_MIN =
(Measured Velocity * VF_NYQUIST_LOW) / (Sensor
Spacing). Example: (10 ft/sec*0.3) / 0.2 = 15Hz

4047 2

Float

VF_CENTROID_WI
DTH

Define width of peak to use in calculation of flow rate.

4049 2

Float

VF_SEARCH_LIMIT
_LOW

Define low end of velocity search range to use for
determining flow velocity. Defined by: Velocity_Min =
(FREQ_MAX * Sensor Spacing) /
(VF_SEARCH_LIMIT_LOW). Example: at 10ft/sec* (10
ft/sec*0.7) / 0.2 = 35Hz then (35Hz * 0.2) / 0.9 = 7.78
ft/sec.

4051 2

Float

VF_SEARCH_LIMIT
_HIGH

Define high end of velocity search range to use for
determining flow velocity. Defined by: Velocity_Max =
(FREQ_MIN * Sensor Spacing) /
(VF_SEARCH_LIMIT_HIGH). Example: at 10ft/sec* (10
ft/sec*0.3) / 0.2 = 15Hz then (15Hz * 0.2) / 0.15 = 20
ft/sec.

4053 2

Float

VF_NYQUIST_INIT_
VAL

This parameter selects the k value (from k-w) where the
algorithm initially searches for the flow rate.