Installation

MAN-TROIG (Ver. 1.403)

www.elmomc.com

60

3.12. Communications

The communication interface may differ according to the user’s hardware. The Trombone can
communicate using the following options:

a.

RS-232, full duplex

b.

CAN

RS-232 communication requires a standard, commercial 3-core null-modem cable connected
from the Trombone to a serial interface on the PC. The interface is selected and set up in the
Composer software.

In order to benefit from CAN communication, the user must have an understanding of the basic
programming and timing issues of a CAN network.

For ease of setup and diagnostics of CAN communication, RS-232 and CAN can be used
simultaneously.

3.12.1. RS-232 Communication

Connecting the RS-232 communication cable:
Connect the shield to the ground of the host (PC). Usually, this connection is soldered internally
inside the connector at the PC end. You can use the drain wire to facilitate connection.
The RS-232 communication port is non-isolated.

Ensure that the shield of the cable is connected to the shield of the connector used for RS-232
communications. The drain wire can be used to facilitate the connection.

Pin (J1)

Signal

Function

1

RS232_Rx

RS-232 receive

2

RS232_Tx

RS-232 transmit

3

RS232_COMRET

Communication return

Table 11: RS-232 Pin Assignments

Figure 34: RS-232 Connection Diagram