4.3. Power Ratings

Feature

Units

12/400 16/400 R17/400 R22/400 8/800

12/800

R11/800 R16/800

Minimum supply

voltage

VDC

S suffix in P/N*: 50

No S suffix in P/N: 100

S suffix in P/N*: 95+

Nominal supply

voltage

VDC

325

560 for 400 VAC
680 for 480 VAC

Maximum supply

voltage

VDC

400

780

Maximum continuous

power output

W

Up to 10 kW of continuous qualitative power

Efficiency at rated

power (at nominal

conditions)

%

> 98

Auxiliary supply

voltage option

VDC

18 V to 30 V

Only for Control Supply S suffix Model

Auxiliary power

supply

VA

≤5 VA without external loading

≤8 VA with full external loading

Continuous current

limit (Ic) Amplitude

sinusoidal/DC

trapezoidal

commutation

A

12

16

17

22

8

12

11

16

Sinusoidal continuous

RMS current limit (Ic)

A

8.5

11.3

12

15.5

5.7

8.5

7.8

11.3

Peak current limit

A

2 x Ic

No peak

2 x Ic

No peak

Weight

g (oz)

250 g (8.8 oz)

Dimensions

mm

(in)

111 x 76 x 30 (4.33" x 2.95" x 1.18")

Digital in/Digital out/

Analog in

6/4/1

Mounting method

PCB Mounted

*See page 17 for details on the part number. The S suffix appears in models where there is a
24 V control supply. If there is no S suffix, the control power supply operates from the main
power.

Note on current ratings:

The current ratings of the Trombone are given in units of DC

amperes (ratings that are used for trapezoidal commutation or DC motors). The RMS
(sinusoidal commutation) value is the DC value divided by 1.41.