Tachometer*
Feature
Details
Tachometer format
Differential
Maximum operating differential voltage for TAC1+, TAC1-
±20 V
Maximum absolute differential input voltage for TAC1+, TAC1- ±25 V
Maximum operating differential voltage for TAC2+, TAC2-
±50 V
Maximum absolute differential input voltage for TAC2+, TAC2- ±60 V
Input resistance for TAC1+, TAC1-
46 kΩ
Input resistance for TAC2+, TAC2-
100 kΩ
Resolution
14 bit
* Only one Tachometer port can be used at a time (either TAC1+/TAC1- or TAC2+/TAC2-).
TAC1+/TAC1- is used in applications with a Tachometer of less than 20 V.
TAC2+/TAC2- is used in applications with a Tachometer of 20 V to 50 V.
4.6.2.7.
Potentiometer
Feature
Details
Potentiometer Format
Single-ended
Operating Voltage Range
0 to 5 V supplied by the Trombone
Potentiometer Resistance
100 Ω to 1 kΩ above this range, linearity is
detrimentally affected
Input Resistance
100 kΩ
Resolution
14 bit