4.3.1.
Auxiliary Supply
This table applies only to the models with an S suffix. See page 17 for further details on the part
number.
Feature
Details
Auxiliary power supply
Isolated DC source only
Auxiliary supply input voltage
18 to 30 VDC
Auxiliary supply input power
< 8 VA (This includes the 5 V/2 x 200 mA load for the
main and auxiliary encoders)
Note:
An S-type drive will not operate unless it has the Aux. supply (Mandatory).
4.4. Environmental Conditions
Feature
Details
Operating ambient temperature
according to IEC60068-2-2
0 °C to 40 °C (32 °F to 104 °F)
Storage temperature
-20 °C to +85 °C ( -4 °F to +185 °F)
Maximum non-condensing humidity
according to IEC60068-2-78
95%
Maximum Operating Altitude
2,000 m (6562 feet)
Mechanical Shock
according to IEC60068-2-27
15g / 11ms Half Sine
Vibration
according to IEC60068-2-6
5 Hz ≤ f ≤ 10 Hz: ±10mm
10 Hz ≤ f ≤ 57 Hz: 4G
57 Hz ≤ f ≤ 500 Hz:5G
Feature