3.9. Communications

The communication interface may differ according to the user’s hardware. The Solo Guitar can
communicate using the following options:

RS-232, full duplex

CAN

RS-232 communication requires a standard, commercial 3-core null-modem cable connected
from the Solo Guitar to a serial interface on the PC. The interface is selected and set up in the
Composer software.
In order to benefit from CAN communication, the user must have an understanding of the basic
programming and timing issues of a CAN network.
For ease of setup and diagnostics of CAN communication, RS-232 and CAN can be used
simultaneously.

3.9.1.

RS-232 Communication

To connect the RS-232 communication cable

1.

Connect the shield to the ground of the host (PC). Usually, this connection is soldered

internally inside the connector at the PC end. You can use the drain wire to facilitate
connection.

2.

The RS-232 communication port is non-isolated.

Pin (J1)

Signal

Function

9

RS232_Tx

RS-232 transmit

10

RS232_Rx

RS-232 receive

11

RS232_COMRET

Communication return

Pin Positions


Table 12: RS-232 Pin Assignments