Chapter 3:

Installation

The Falcon must be installed in a suitable environment and properly connected to its voltage
supplies and the motor.

3.1. Before You Begin

3.1.1.

Site Requirements

You can guarantee the safe operation of the Falcon by ensuring that it is installed in an
appropriate environment.

Feature

Value

Ambient operating temperature

-40 °C to +70 °C (-40 °F to 160 °F)

Maximum operating altitude

12,000 m (39370 feet)

Maximum non-condensing humidity 95%

Operating area atmosphere

No flammable gases or vapors permitted in area

Models for extended environmental conditions are available.

Caution:
The Falcon dissipates its heat by natural convection. The maximum ambient
operating temperature of -40 °C to +70 °C (-40 °F to 160 °F) must not be
exceeded.

3.1.2.

Hardware Requirements

The components that you will need to install your Falcon are:

Component

Wire

Described
in Section

Drawing

Main Power
Cable

VP+ - red
PR- black

3.4.2.2

Motor Cable

M1 M2 M3-

white

3.4.2.1