Environmental conditions, Falcon connections, Environmental conditions 4.5. falcon connections – ElmoMC ExtrIQ Digital Servo Drives-Falcon User Manual

Page 60

Advertising
background image

Falcon Installation Guide

Technical Specifications

MAN-FALIG (Ver. 1.502)

www.elmomc.com

60

4.4. Environmental Conditions

Feature

Operation Conditions

Range

Ambient

Temperature

Range

Non-operating conditions -50 °C to +100 °C (-58 °F to 212 °F)

Operating conditions

-40 °C to +70 °C (-40 °F to 160 °F)

Temperature

Shock

Non-operating conditions -40 °C to +70 °C (-40 °F to 160 °F) within 3

min

Altitude

Non-operating conditions Unlimited

Operating conditions

-400 m to 12,000 m (-1312 to 39370 feet)

Humidity

Non-operating conditions Up to 95% non-condensing humidity at 35 °C

(95 °F)

Operating conditions

Up to 95% non-condensing humidity at 25 °C
(77 °F), up to 90% non-condensing humidity
at 42 °C (108 °F)

Vibration

Operating conditions

20 Hz to 2000 Hz, 14.6 g

Mechanical

Shock

Non-operating conditions ±40 g; Half sine, 11 msec

Operating conditions

±20 g; Half sine, 11 msec

4.5. Falcon Connections

The following connectors are used for wiring the Falcon.

Pins Type

Maker & Part

No.

Port

-

14 AWG Wires

FLDW CO311-14
Rychem

VP+, PR

M1, M2, M3

3

M4 screws

PE, PE, PE

-

20 AWG wires

FLDW CO311-20
Rychem

24v

Connector Location

Table 17: Connectors on the Bottom of the Falcon

Optional

Backup

Power

Ground

Power and

Motor

Advertising