Eagle Installation Guide

Installation

MAN-EAGIG (Ver. 1.902)

www.elmomc.com

28

Figure 5: AC Motor Power Connection Diagram

3.4.2.2.

Connecting the DC Power

The Power stage of the Eagle is fully isolated from other sections of the Eagle, such as the control
stage and the heat sink. This contributes very significantly to the safety and the EMI immunity of
the Eagle. In addition it simplifies the requirements of the DC power supply used to power the DC
bus of the Eagle and allows also the operation with a non-isolated DC power source.

3.4.2.2.a

Operation with an Isolated DC Power Supply

Figure 6: Isolated DC Power Supply

In this case, the isolation is achieved by the isolation transformer. It is highly recommended to
connect the network PE to the Return (negative terminal) of the Power Supply.