Opening the ApplicationTemplate PackML

Visualisation of the machine modules

36

Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

7.6

Visualisation of the machine modules

• If, for instance, Machine Control has been

selected, the fields Al[01...04] of

L_EATP_Alarm_PackML serve to trigger

alarms.

• Possible reactions (Reac.) are: Abort, Stop,

Error, SystemFault, Warning, Information.

• The machine module transmits the

reaction type to the higher-level machine

module. The desired response to the alarm

can be programmed individually, except

for the commands Abort/Stop.

• If no error response has been programmed,

the state machine remains in the current

state.

• The Modules button calls the detailed view

for the machine modules.

• Click the desired machine module to show

the respective status and further details.

• All alarm messages are visible in the global

alarm list which can be called via the Alarm

List button. The global alarm list provides

an overview of all alarms occurred.

• The Alarm Quit button has to be pressed to

reset the error. The reason for the tripping

has to be removed. Then, the

corresponding alarm can be reset.