3 integrating machine modules in the mmt, Integrating machine modules in the mmt, Folder – Lenze ApplicationTemplate PackML (PLC Designer R3-x) User Manual

Page 42: Working with the applicationtemplate packml

Advertising
background image

Working with the ApplicationTemplate PackML

Integrating machine modules in the MMT

42

Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.3

Integrating machine modules in the MMT

A machine module (created on the basis of the EmptyModule_PackML machine module template)

has to be integrated into the MachineModuleTree (MMT) in order to integrate it functionally into

the ApplicationTemplate PackML.

[8-1]

Example: MachineModuleTree in the ApplicationTemplate PackML

How to proceed:

1. Double-click the

A10_MachineModuleTree folder in the device view.

Double-click MMT (PRG).

Note: The programming language of MMT (PRG) is CFC (Continuous Function Chart).

• In the Tools dialog window, click the

Block button.

• Create the new FB via drag-and-drop.

• Double-click the

area of the FB, click the

button.

Use the Input assistance from the

Application element...

• ...to assign the MFB_CrossCutter FB.
• ...to assign the CrossCutter instance.

Note: Go to the Input assistant and select the  Insert with namespace prefix when

assigning the instance name.

2. Specify the relative address for the machine module.

• In the Tools dialog window, click the

Input button.

• Add the new input at MM_Address
• Assign the relative address (example: "3").