Working with the ApplicationTemplate PackML

Mapping the actual machine structure: Add devices

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

2. Add an EtherCAT slave below the EtherCAT Master: Right-click the EtherCAT Master

Add device:

Select the desired device from the selection list

.

The »PLC Designer« provides a "fieldbus scan" during which the devices connected to the

fieldbus are automatically detected.
Further information is provided in the "Controller-based Automation EtherCAT" section of

the online help for the »PLC Designer« and in the Controller-based Automation EtherCAT

communication manual (KHB).

Repeat the

Add device until all slaves connected to the fieldbus are implemented in the

device view.
Allocate unique designations to the slaves inserted

(example: "L_94_HL_ActuatorSpeed").
The names can be selected freely and must …

• only contain the characters "A ... Z", "a ... z", "0 ... 9", or "_";
• not start with a digit.

You can enter a name by clicking the element.
Example: