Mapping the actual machine structure: add devices, Working with the applicationtemplate packml – Lenze ApplicationTemplate PackML (PLC Designer R3-x) User Manual

Page 38

Advertising
background image

Working with the ApplicationTemplate PackML

Mapping the actual machine structure: Add devices

38

Lenze · ApplicationTemplate PackML · 1.0 EN - 05/2014

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

8.1

Mapping the actual machine structure: Add devices

The ApplicationTemplate PackML contains a predefined structure that can be extended by the

individual requirements. Carry out the following steps to map the actual machine structure.

How to create the control configuration in the »PLC Designer«:

1. Open the context menu of the target system and execute the command

Append device

in order to extend the control configuration with

"EtherCAT Master".

Note!

Before creating an EtherCAT configuration in »PLC Designer«, ensure that the following

conditions have been met:

• The sequence of the EtherCAT slaves in the device view must correspond to the

physical arrangement of the EtherCAT topology.

• Select the cycle times according to the technical data, from 1 ... 10 ms.

Advertising