Lenze E94AxHE Technology Application Actuating drive - Speed User Manual

Page 14

Advertising
background image

9400 Technology applications | Actuator – speed

Short setup

Step 3: Transferring the application to the controller

14

L

EDS94TA10010xxxx EN 1.1 - 10/2008

3.5

Step 3: Transferring the application to the controller

1.

Update devices.

– Set the checkmark in the control field Recreate all.
– Click Create to start the compiling process.

2.

Go online and transfer the application to the controller.

– With an online connection, the »Engineer« displays the current controller parameter

settings with a yellow background colour:

Note!

The transferred application is always stored in the first application memory

location in the memory module of the controller.
The preinstalled technology applications on the following memory locations are

still available.

Note!

The machine reference speed is the speed of the conveyor belt when the motor

runs at reference speed (C00011) with 100 % setpoint.
• The indicated value corresponds to a speed of 83.7 m/min.
• For reaching a speed of 100 m/min with 10 V at the setpoint input, the

setpoint gain can be increased to 120 % or the reference speed to 2010 rpm.