9400 Technology applications | Actuator – speed

Parameter setting & configuration

Actual value and status signals

32

L

EDS94TA10010xxxx EN 1.1 - 10/2008

4.10

Actual value and status signals

The following tables contain the Lenze assignment of the analog and digital outputs for

the technology application "actuator - speed".

r

The default signal configuration if required can be easily changed by parameterising

the multiplexer parameters assigned.

Analog outputs

Digital outputs

State bus

Display elements

Terminal X3

Signal (Lenze setting)

Signal configuration

AO1

Speed setpoint

• Scaling: ±10 V ≡ motor reference speed (C00011)

C03110/1

AO2

Filtered torque setpoint

• Scaling: ±10 V ≡ Motor reference torque (C00057/2)

C03110/2

Terminal X4

Signal (Lenze setting)

Signal configuration

DO1

Status "Drive ready"

• DC-bus voltage is available and no error has occurred.

C03100/1

DO2

Status "Speed follower enabled"

• The speed follower has been enabled via the digital input DI2.

C03100/2

DO3

Status "Speed follower in limitation"

• The enabled speed follower is in the limitation for more than

100 ms.

• The setpoint is limited to the upper or lower speed limit value

(C00909/1 or C00909/2) .

C03100/3

DO4

Status "Error active acknowledgement is required"

• A monitoring function with the error response "Error" or "Quick

stop by trouble" has been activated and the controller is in the

status "Error active" or "Quick stop by trouble active".

C03100/4

Terminal X2

Signal (Lenze setting)

Signal configuration

SB

Status "Speed follower in limitation"

• The enabled speed follower is in the limitation for more than

100 ms.

• The setpoint is limited to the upper or lower speed limit value

(C00909/1 or C00909/2) .

• The state bus is put in the "error" status.

C03100/5

User LED

Signal (Lenze setting)

Signal configuration

Status "Speed follower enabled"

• The speed follower has been enabled via the digital input DI2.

C03100/6

GA

AO1

AO2

GO

24O

DO1

DO2

DO3

DO4

GE

24E

SB