2 setpoint inversion, Setpoint inversion (c 20), 9400 technology applications | actuator – speed – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual

Page 20

Advertising
background image

9400 Technology applications | Actuator – speed

Parameter setting & configuration

Speed setpoint conditioning

20

L

EDS94TA10010xxxx EN 1.1 - 10/2008

4.3.2

Setpoint inversion

[4-4]

Setpoint inversion (schematic diagram)

Via the digital input DI3 the effective direction of the (bipolar) setpoint can be inverted, if

required.

r

Parameter setting: Tab Application parameters  dialog level Overview  Ramp

generator

Gain

Invert setpoint

Selection

LS_Speed...

M

Speed
setpoint

DI2

DI3

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed setpoint

AIN1

M

v

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

DIGIN 3  Invert direction of rotation

C03009/1