8 brake control, 9400 technology applications | actuator – speed, Parameter setting & configuration brake control – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual

Page 27

Advertising
background image

EDS94TA10010xxxx EN 1.1 - 10/2008

L

27

9400 Technology applications | Actuator – speed

Parameter setting & configuration

Brake control

4.8

Brake control

[4-10] Basic function "Brake control" (schematic diagram)

r

Parameter setting: Tab Application parameters  dialog level Overview  Brake control

The basic function "Brake control" serves

to the wear free control and monitoring of

a holding brake.
In the simplest case, an optionally

available brake module is used.
Alternatively the holding brake can also be

controlled and monitored via the digital

inputs/outputs.

LS_ManualJog

n

t

и

з

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

LS_Speed...

M

Speed
setpoint

n

t

LS_Stop

internal
status machine

DI2

DI6

DI7
DI8

DI1

Status

machine

(basic drive

functions)

Basic drive functions

M

v

и
з

Note!

In the Lenze setting the brake control is switched off to reach a safe status after

mains connection.

Parameter

Lenze setting

Value Unit

C02580

Operating mode of brake

Brake control off

C02581

Brake activation threshold

50 rpm

C02582

Brake response to pulse inhibit

Activate brake immediately

C02583

Status input monitoring

Not active

C02585

Brake control polarity

Not inverted

C02586

Starting torque 1

0.00 Nm

C02587

Starting torque 2

0.00 Nm

C02588

Starting torque source

Starting torque 1/2

C02589

Brake closing time

100 ms

C02590

Brake opening time

100 ms

C02591

Waiting time - status monitoring

100 ms

C02593

Waiting time - brake activation

0.000 s

C02594

Test torque

0.00 Nm

C02595

Permissible angle of rotation

5 °

C02596

Grinding speed

100 rpm

C02597

Accel./decel. time - grinding

1.000 s

C02598

Grinding ON time

0.5 s

C02599

Grinding OFF time

0.5 s

Advertising