12 parameterisable function blocks, 1 l_devapplerr1, 2 l_tbdelay1 – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual

Page 34: 9400 technology applications | actuator – speed

Advertising
background image

9400 Technology applications | Actuator – speed

Parameter setting & configuration

Parameterisable function blocks

34

L

EDS94TA10010xxxx EN 1.1 - 10/2008

4.12

Parameterisable function blocks

This subchapter lists all relevant parameterisable function blocks of the technology

application and the corresponding parameters in alphabetical order.

4.12.1

L_DevApplErr1

4.12.2

L_TbDelay1

Is an instance of

Function

L_DevApplErr

Error handling



Application error messages (C 33)

Parameter

Possible settings

Information

C05900

980

999 Module ID

C05901/1...8

0

65535 Error ID

C05902/1...8

Error response

0 None
1 Fault
2 Trouble
3 Quick stop by trouble
4 Warning locked
5 Warning
6 Information

Is an instance of

Function

L_TbDelay

Delay of the signal MI_bSpeedCtrlLimited for error handling

Parameter

Possible settings

Information

C03550

Selection of the edge to be delayed

0 Rising edge

Lenze setting

1 Falling edge
2 Both edges

C03551

0.000

s

60.000 Delay time

• Initialisation: 0.100 s

Advertising