EDS94TA10010xxxx EN 1.1 - 10/2008

L

31

9400 Technology applications | Actuator – speed

Parameter setting & configuration

Signal configuration

Output port "LPortStatus1"
The output port LPortStatus1 is intended for the connection with a higher-level control.

Output port "LPortStatus2"

Signal (Lenze setting)

Output port

Signal configuration

Status word 1

Drive ready  Status word 1 bit 00

C03121/1

FALSE  Status word 1 bit 01

C03121/2

Operation enabled  Status word 1 bit 02

C03121/3

Error is active  Status word 1 bit 03

C03121/4

FALSE  Status word 1 bit 04

C03121/5

Quick stop is active  Status word 1 bit 05

C03121/6

Drive is ready to start  Status word 1 bit 06

C03121/7

Warning is active  Status word 1 bit 07

C03121/8

FALSE  Status word 1 bit 08

C03121/9

FALSE  Status word 1 bit 09

C03121/10

FALSE  Status word 1 bit 10

C03121/11

Motor control in limitation  Status word 1 bit 11

C03121/12

FALSE  Status word 1 bit 12

C03121/13

FALSE  Status word 1 bit 13

C03121/14

FALSE  Status word 1 bit 14

C03121/15

FALSE  Status word 1 bit 15

C03121/16

Signal (Lenze setting)

Output port

Signal configuration

Status word 2

FALSE  Status word 2 bit 00

C03122/1

FALSE  Status word 2 bit 01

C03122/2

FALSE  Status word 2 bit 02

C03122/3

FALSE  Status word 2 bit 03

C03122/4

FALSE  Status word 2 bit 04

C03122/5

FALSE  Status word 2 bit 05

C03122/6

FALSE  Status word 2 bit 06

C03122/7

FALSE  Status word 2 bit 07

C03122/8

FALSE  Status word 2 bit 08

C03122/9

FALSE  Status word 2 bit 09

C03122/10

FALSE  Status word 2 bit 10

C03122/11

FALSE  Status word 2 bit 11

C03122/12

FALSE  Status word 2 bit 12

C03122/13

FALSE  Status word 2 bit 13

C03122/14

FALSE  Status word 2 bit 14

C03122/15

FALSE  Status word 2 bit 15

C03122/16

Advertising