3 speed ramp generator, 9400 technology applications | actuator – speed – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual

Page 21

Advertising
background image

EDS94TA10010xxxx EN 1.1 - 10/2008

L

21

9400 Technology applications | Actuator – speed

Parameter setting & configuration

Speed setpoint conditioning

4.3.3

Speed ramp generator

[4-5]

Ramp generator (schematic diagram)

In order to avoid setpoint step-changes the speed setpoint passes a ramp generator with a

parameterisable acceleration/deceleration and S-ramp time before it is transmitted to the

basic drive function "Speed follower".

r

Parameter setting: Tab Application parameters  dialog level Overview

Gain

Invert setpoint

Selection

LS_Speed...

M

Speed
setpoint

DI2

DI3

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed setpoint

AIN1

M

v

Parameter

Lenze setting

Value Unit

C03502

Basic acceleration time

1.000 s

C03503

Basic deceleration time

1.000 s

C03504

Basic S-ramp time

0.100 s

C03510

Profile mode

Linear ramps