5 manual jog, Manual jog (c 24), 9400 technology applications | actuator – speed – Lenze E94AxHE Technology Application Actuating drive - Speed User Manual

Page 24: Parameter setting & configuration manual jog

Advertising
background image

9400 Technology applications | Actuator – speed

Parameter setting & configuration

Manual jog

24

L

EDS94TA10010xxxx EN 1.1 - 10/2008

4.5

Manual jog

[4-7]

Basic function "Manual jog" (schematic diagram)

For the setting-up operation the basic function "Manual jog" is available. It is requested via

the digital input DI6. If no other basic function and error status are active, enable is carried

out and the manual jog via the digital inputs DI7 and DI8 is possible.

r

Parameter setting: Tab Application parameters  dialog level Overview  Manual jog

LS_ManualJog

n

t

и

з

LS_Brake

n

t

LS_Limiter

n

t

LS_Quickstop

STOP

Gain

Invert setpoint

Selection

LS_Speed...

M

Speed
setpoint

n

t

LS_Stop

internal
status machine

DI2

DI6

DI7
DI8

DI1

DI3

DI4

OUT

IN

Ramp generator

%

1

%

2

%

15

Fixed setpoints

Status

machine

(basic drive

functions)

Speed setpoint

Basic drive functions

AIN1

M

v

и
з

Parameter

Lenze setting

Value Unit

C02620

Manual jog: Speed 1

360.0000 unit/s

C02621

Manual jog: Speed 2

720.0000 unit/s

C02622

Manual jog: Acceleration

360.0000 unit/s

2

C02623

Manual jog: Deceleration

1440.0000 unit/s

2

C02624

Manual jog: S-ramp time

0.100 s

Control inputs of the function

Signal configuration

Lenze setting

Control input

(Multiplexer parameters)

DIGIN 6  Request manual jog

C03155/1

DIGIN 7  Activate positive manual jog

C03155/2

DIGIN 8  Activate negative manual jog

C03155/3

FALSE  Activate 2. speed

C03155/4

Advertising