SWIFT 10 ATV Sensors

126

Troubleshooting

A two-time-per-revolution

of tire signal is showing up

when the vehicle is driving
straight on a flat surface.

Gain settings: Verify that the TI electronics

calibration file gain settings have not been

modified. Using the T2IXFER program, upload
the current TI settings and compare them to the

original gain setting on the disk provided.

Bridge Failure: If a single bridge is failing due

to overstress, overload induced crack, and so on,

the results could appear as this type of output.
To verify that this is the cause, use the

TI2XFER program to upload the current TI

settings after a zeroing procedure. Load the
transducer for several cycles, without inducing

heat (drive vehicle for a few cycles but do not

use excessive brake heating). Rezero the TI
electronics. Use TI2XFER to upload the new

zero values. Compare them to the previously

recorded zero values. These values should not
change by more than 0.01 to 0.03 for two zeroes

done at the same conditions, on the same

transducer. If the changes are much larger,
remove the transducer from vehicle and contact

MTS.

Troubleshooting Guide (part 9 of 10)

S

YMPTOM

P

OSSIBLE

C

AUSES

S

OLUTION