130

 What dwell times should be used with the LS1 coils sold with my system?

 With a 12V charging system.

 From idle to approximately 4,000 RPM? Use about 3.0 milliseconds near idle

and no more than about 4.0 milliseconds at approximately 4,000 RPM.

 From approximately 4,100 - Max RPM? Use no more than about 6 milliseconds

of total dwell time at max RPM.

 With a 16V charging system.

 From idle to approximately 4,000 RPM? Use about 2.0 milliseconds near idle

and no more than about 3.0 milliseconds at approximately 4,000 RPM.

 From approximately 4,100 - Max RPM? Use no more than about 4.5

milliseconds of total dwell time at max RPM.

 For LSx COP engines, make sure the cam sync override box in the “Operating Configuration”

drop down is

not

checked.

 The Ford Mod Motor COP system

must

have the “Override Cam Sync Test box, checked.