BigStuff3 Pro SEFI System

Version 2.1 – February 2011

56

Fill – Choosing “Fill” will open a secondary drop down- screen which allows the selected cells

to be changed to the value inputted into the window.

Multiply – Choosing “Multiply” will open a secondary drop down-screen which allows the

values of the selected cells to be changed by the ” Multiply” value inputted into the window.
For example, if the values in the cells selected are 13 and the inputted “Multiply” value was 80,
the new cell values would be 10.4.

Interpolate – If a series of cells in the same row are selected and the “Interpolate” “cell-fill”

option is selected the ECU will use the value in the cell all the way to the left and the cell value
all the way to the right and interpolate the numbers in between so that the values are linear.

Cell Values Selected in a Row

14

14

13.5

13.8

Interpolated Result from Cell Values Selected Above

14

13.9

13.8

13.8


If a series of cells in the same column are selected and the “Interpolate” option is selected the ECU
will use the value in the cell all the way at the bottom and the cell value all the way at the top and
interpolate the numbers in between so that the values are linear.

Cell
value to
the left

Cell
value to
the left