Installation Instructions

FINAL INSTALLATION CHECKLIST

11

• Check to make sure the circuit breaker is closed

(RESET) or the circuit fuses are replaced.

• Be sure power is in service to the building.
• Note (on some models): If the clock flashes "bad"

and then "LinE" with a loud tone, the neutral con-

nection to the range is miswired. Check the termi-

nal block connections and/or house wiring to

correct.

• Check to be sure that all packing materials and

tape have been removed. This will include tape

on metal panel under control knobs (if appli-

cable), adhesive tape, wire ties, cardboard and

protective plastic. Failure to remove these materi-

als could result in damage to the appliance once

the appliance has been turned on and surfaces

have heated.

• Check to make sure that the rear leveling leg is

fully inserted into the Anti-Tip bracket and that the

bracket is securely installed.

OPERATION CHECKLIST

12

• Turn on one of the surface units to observe that

the element glows within 60 seconds. Turn the unit

off when glow is detected. If the glow is not de-

tected within the time limit, recheck the range

wiring connections. If change is required, retest

again. If no change is required, have building wir-

ing checked for proper connections and voltage.

• Check to make sure the Clock (on models so

equipped) display is energized. If a series of hori-

zontal red lines appears in the display, disconnect

power immediately. Recheck the range wiring

connections. IF change is made to connections,

retest again. If no change is required, have build-

ing wiring checked for proper connections and

voltage. It is recommended that the clock be

changed if the red lines appear.

• Be sure all range controls are in the OFF position

before leaving the range.