How to Program the Drive

3. Press the Enter key and the newly selected parameter name, number, and value

is displayed.

If the parameter number you entered does not exist, an error message is displayed.

The cursor will blink to indicate that additional input is expected.

Press the Escape key or Enter key to return to the previous Program Group
parameter.

Change a Parameter Value

There are two methods for changing the value of a Program Group parameter.

Important:

The values of some parameters can be changed only when the drive
is stopped. If you start the drive while changing the value of one
of these parameters, the new value will not be accepted and an the
following error message is displayed.

Method 1 – Scroll Parameter Values

1. Display the Program Group parameter that you want to edit.

2. Press the Select key.

The cursor will blink at the first digit of the parameter value to indicate that the
value can be changed.

3. Press the Up or Down arrow key to increase or decrease the parameter to the

desired value.

Press and hold the Up or Down arrow key to scroll through the parameter
values. If the high or low limit for the parameter value is reached, release the
Up or Down arrow key and press and hold again to continue scrolling from the
opposite limit.